欧美中日韩影视一区,第四色色图,免费av在线久久,妖精丝袜久久精品一区,色香蕉伊人在线,人人爽97超碰人妻,噜噜噜亚洲精品,国产一区二区主播精品,大香蕉伊人一区二区

Home > Products



PRODUCT


Wet Alarm Valve-Grooved

概述.jpg


Wet system alarm valve is specially designed for fire protection system use. The valve is an important component in Wet system automatic sprinkler and fire extinguishing system and suitably applied to the system which is well and broadly used among the automatic sprinkler and fire extinguishing system.

 Working principle: The valve disc switched on/off is owing to the water pressure rises up or lowers down on the piping system. When water supply pressure fluctuates by a little under normal working in non-alarming state, the by-pass balance pipe keeps the water pressure in balance above and below the valve disc, therefore maintaining the valve disc closed and avoiding alarm to happen by accident. In case of fire, the glass bulb of the close-type sprinkler will break up to spray water as a result to cause the water pressure lower down on the piping system. Owing to a differential pressure exists between the water supply pipe and the piping system on the other side, the valve disc will then open to actuate pressure switch and water flow indicator. Upon the fire protection control center receiving alarm signal, the fire protection pump will be switched on directly to spray water and extinguish fire, and then the water powered alarm starts to alarm to alert people on the spot to evacuate as soon as possible. 

Application: The Wet system automatic sprinkler and fire extinguishing system is suitable for use in areas with ambient temperature higher than 4 ℃ and lower than 70℃. When ambient temperature is lower than 4 ℃, the Wet system automatic sprinkler and fire extinguishing system may also be applied. However, the pipeline behind the fire alarming valve shall be set up freeze resistant measure. When ambient temperature is higher than 70 ℃, the Wet system automatic sprinkler and fire extinguishing system shall not be applied. 

 



技術(shù)特點(diǎn).jpg


A.The main valve adopts swing type straight waterway structure, with low flow rate resistance at large flowing area.

B.High quality of ductile cast iron provided materials reference for valve body and cover production which are electro-statically coated with epoxy resin powder; valve disc is made of rubber-encapsulated copper to prevent rust and jamming from occurring under normal working in non-alarming state.

C.The fire alarming pipeline is equipped with delayer which could avoid alarming to happen by accident when water supply pressure fluctuates by little to flush the valve disc open.

D.With a view to preventing the pipeline system from leaking(no more than 15L/min) or occurring large differential pressure between upper and lower chamber due to fluctuation of water supply pressure,  the valve disc will open occasionally to cause alarm by accident. The valve is equipped with balancing pipe which could automatically balance the pressure between upper and lower chamber to avoid happening false alarm.

E.The valve has the characteristics of automatic tracing fire source and automatic switch-on system

F.Seawater resistance and stainless steel materials to be provided for application



技術(shù)參數(shù).jpg


 



安裝示意圖.jpg




工程案例.jpg


Copyright @ 2018 Guangdong Yongquan Valve Technology Co., Ltd, All rights reserved

Record number:Guangdong 17110555 number

CONTACT

Tel:0757-86568315 / 86561111(Foshan Plant)、020-81892048(Guangzhou Sales Center)、010-63396396(Beijing Sales Center)


Add:Longgao Rd., Jiujiang Town, Nanhai District,  Foshan City, Guangdong Province, China


Products

Wet Alarm Valve-Grooved

概述.jpg


Wet system alarm valve is specially designed for fire protection system use. The valve is an important component in Wet system automatic sprinkler and fire extinguishing system and suitably applied to the system which is well and broadly used among the automatic sprinkler and fire extinguishing system.

 Working principle: The valve disc switched on/off is owing to the water pressure rises up or lowers down on the piping system. When water supply pressure fluctuates by a little under normal working in non-alarming state, the by-pass balance pipe keeps the water pressure in balance above and below the valve disc, therefore maintaining the valve disc closed and avoiding alarm to happen by accident. In case of fire, the glass bulb of the close-type sprinkler will break up to spray water as a result to cause the water pressure lower down on the piping system. Owing to a differential pressure exists between the water supply pipe and the piping system on the other side, the valve disc will then open to actuate pressure switch and water flow indicator. Upon the fire protection control center receiving alarm signal, the fire protection pump will be switched on directly to spray water and extinguish fire, and then the water powered alarm starts to alarm to alert people on the spot to evacuate as soon as possible. 

Application: The Wet system automatic sprinkler and fire extinguishing system is suitable for use in areas with ambient temperature higher than 4 ℃ and lower than 70℃. When ambient temperature is lower than 4 ℃, the Wet system automatic sprinkler and fire extinguishing system may also be applied. However, the pipeline behind the fire alarming valve shall be set up freeze resistant measure. When ambient temperature is higher than 70 ℃, the Wet system automatic sprinkler and fire extinguishing system shall not be applied. 

 



技術(shù)特點(diǎn).jpg


A.The main valve adopts swing type straight waterway structure, with low flow rate resistance at large flowing area.

B.High quality of ductile cast iron provided materials reference for valve body and cover production which are electro-statically coated with epoxy resin powder; valve disc is made of rubber-encapsulated copper to prevent rust and jamming from occurring under normal working in non-alarming state.

C.The fire alarming pipeline is equipped with delayer which could avoid alarming to happen by accident when water supply pressure fluctuates by little to flush the valve disc open.

D.With a view to preventing the pipeline system from leaking(no more than 15L/min) or occurring large differential pressure between upper and lower chamber due to fluctuation of water supply pressure,  the valve disc will open occasionally to cause alarm by accident. The valve is equipped with balancing pipe which could automatically balance the pressure between upper and lower chamber to avoid happening false alarm.

E.The valve has the characteristics of automatic tracing fire source and automatic switch-on system

F.Seawater resistance and stainless steel materials to be provided for application



技術(shù)參數(shù).jpg


 



安裝示意圖.jpg




工程案例.jpg


Copyright @ 2018 Guangdong Yongquan Valve Technology Co., Ltd, All rights reserved

Record number:Guangdong 17110555 number

   
 
X
 
   
涟水县| 张家川| 庆城县| 治多县| 井陉县| 轮台县| 九龙坡区| 罗山县| 富裕县| 刚察县| 丰县| 体育| 武邑县| 盐城市| 南华县| 开封县| 浮梁县| 临泽县| 疏附县| 富川| 盐亭县| 荆州市| 新昌县| 府谷县| 兴山县| 石渠县| 如皋市| 孟津县| 罗定市| 深水埗区| 辉南县| 城口县| 札达县| 宝清县| 蕲春县| 定结县| 西丰县| 宁乡县| 千阳县| 南华县| 洞头县|