欧美中日韩影视一区,第四色色图,免费av在线久久,妖精丝袜久久精品一区,色香蕉伊人在线,人人爽97超碰人妻,噜噜噜亚洲精品,国产一区二区主播精品,大香蕉伊人一区二区

Home > Products



PRODUCT


Pre-active Piston Type Alarm Valve

概述.jpg


Pre-action alarm system is a valve module that specially designed for fire protection system use. The system is a kind of control valves mainly consisted of deluge alarm valve and Wet system alarm valve which are concatenated up and down. The system is opened by using manual, mechanical and other ways together with close-type sprinkler, so as to make water flow into sprinkler system in one way automatically and start alarming simultaneously.

Working principle: In case of fire, the heat and smoke fire sensor will be firstly detecting the potential fire and then they send alarm signal to fire alarm controller or fire protection control center. Upon receiving the alarm signal, the fire alarm controller or fire protection control center will send command to switch on the solenoid pilot valve on deluge alarm valve which can be then actuated to open and fill water in fire protection pipeline, and then the water powered alarm starts to alarm. If the fire continues to develop, the glass bulb of the close-type sprinkler will break up to spray water and the pump begins operating automatically.

Application: The pre-action alarm valves system is equipped with close-type sprinkler, combining the technology of fire automatic detecting and alarming with the system of automatic sprinkler and fire extinguishing. When there is no fire happened, low pressure air shall be filled in the system pipelines for purposes of detecting, and therefore the system has dry pipe characteristics. With view to the characteristics of dry pipe, it is suitable for installing in the places that need water for fire extinguishing but can’t by accident spray the wrong place, for example in laboratory, archives, valuables storeroom, and computer facilities as well as valuables warehouse, etc. Some luxurious hotel in overseas will also adopt such system for use. In addition, the pre-action alarm valves system can be installed in areas of high temperature, cold and freezing condition in place of dry system.



技術(shù)特點.jpg


A.High quality of ductile cast iron provided materials reference for valve body and cover production which are electro-statically coated with epoxy resin powder to ensure high ability of corrosion resistance.。

B.Y-pattern wide valve chamber construction with low pressure losses at the highest speed of flow rate; strong anti-cavitation ability and no noises.

C.Main parts are made of stainless steel and copper to prevent rust and jamming from occurring.

D.Compressed air is filled in the pipeline system above the Wet system alarm valve at normal time, protecting the pipe wall, reducing corrosion and easy monitoring the pipeline at any time whether there is leakage happens

E.The distribution pipe behind the fire alarming valve is filled with air instead of water so as to avoid accidental spraying and pipeline leakage occurring. Also used as a preliminary pre-action alarming in low and high temperature areas.

F.Seawater resistance and stainless steel materials to be provided for application



技術(shù)參數(shù).jpg


             

      

       



安裝示意圖.jpg




工程案例.jpg


Copyright @ 2018 Guangdong Yongquan Valve Technology Co., Ltd, All rights reserved

Record number:Guangdong 17110555 number

CONTACT

Tel:0757-86568315 / 86561111(Foshan Plant)、020-81892048(Guangzhou Sales Center)、010-63396396(Beijing Sales Center)


Add:Longgao Rd., Jiujiang Town, Nanhai District,  Foshan City, Guangdong Province, China


Products

Pre-active Piston Type Alarm Valve

概述.jpg


Pre-action alarm system is a valve module that specially designed for fire protection system use. The system is a kind of control valves mainly consisted of deluge alarm valve and Wet system alarm valve which are concatenated up and down. The system is opened by using manual, mechanical and other ways together with close-type sprinkler, so as to make water flow into sprinkler system in one way automatically and start alarming simultaneously.

Working principle: In case of fire, the heat and smoke fire sensor will be firstly detecting the potential fire and then they send alarm signal to fire alarm controller or fire protection control center. Upon receiving the alarm signal, the fire alarm controller or fire protection control center will send command to switch on the solenoid pilot valve on deluge alarm valve which can be then actuated to open and fill water in fire protection pipeline, and then the water powered alarm starts to alarm. If the fire continues to develop, the glass bulb of the close-type sprinkler will break up to spray water and the pump begins operating automatically.

Application: The pre-action alarm valves system is equipped with close-type sprinkler, combining the technology of fire automatic detecting and alarming with the system of automatic sprinkler and fire extinguishing. When there is no fire happened, low pressure air shall be filled in the system pipelines for purposes of detecting, and therefore the system has dry pipe characteristics. With view to the characteristics of dry pipe, it is suitable for installing in the places that need water for fire extinguishing but can’t by accident spray the wrong place, for example in laboratory, archives, valuables storeroom, and computer facilities as well as valuables warehouse, etc. Some luxurious hotel in overseas will also adopt such system for use. In addition, the pre-action alarm valves system can be installed in areas of high temperature, cold and freezing condition in place of dry system.



技術(shù)特點.jpg


A.High quality of ductile cast iron provided materials reference for valve body and cover production which are electro-statically coated with epoxy resin powder to ensure high ability of corrosion resistance.。

B.Y-pattern wide valve chamber construction with low pressure losses at the highest speed of flow rate; strong anti-cavitation ability and no noises.

C.Main parts are made of stainless steel and copper to prevent rust and jamming from occurring.

D.Compressed air is filled in the pipeline system above the Wet system alarm valve at normal time, protecting the pipe wall, reducing corrosion and easy monitoring the pipeline at any time whether there is leakage happens

E.The distribution pipe behind the fire alarming valve is filled with air instead of water so as to avoid accidental spraying and pipeline leakage occurring. Also used as a preliminary pre-action alarming in low and high temperature areas.

F.Seawater resistance and stainless steel materials to be provided for application



技術(shù)參數(shù).jpg


             

      

       



安裝示意圖.jpg




工程案例.jpg


Copyright @ 2018 Guangdong Yongquan Valve Technology Co., Ltd, All rights reserved

Record number:Guangdong 17110555 number

   
 
X
 
   
日土县| 巴东县| 永靖县| 申扎县| 来宾市| 东至县| 循化| 瑞丽市| 韩城市| 邵阳市| 泗阳县| 蒲城县| 休宁县| 阜康市| 施甸县| 宁明县| 瓦房店市| 丰台区| 祁阳县| 三江| 枣阳市| 旬阳县| 淄博市| 日喀则市| 东台市| 田阳县| 循化| 荔浦县| 台中县| 龙江县| 上高县| 奉节县| 盐池县| 新晃| 宣化县| 池州市| 威海市| 邵东县| 岳阳县| 衡东县| 许昌县|